Chang Yih inverter manufacturer

Single phase 220V1HP (mini)

  • single phase vfd, single phase variable frequency drives
  • V/F& Sensorless Vector Control
  • PID Feedback Control & Water Pump PID
  • Automatic torque boost & Slip compensation
  • Energy Saving & Automatic voltage regulation
  • Output Frequency 0.1~400Hz
  • Communication interface RS-485(Baud rate 38400 max.)
  • 8-set speed control & 7-set process control
  • Adjust S curve 、V/F curve & Simple vector control
  • Zero speed holding function & Sleep/Revival Function
  • Process follower 0-10VDC,4-20mA
  • Product Description
  • Product Dimension
  • Product Specifications

230 Series:

Model Number
CY-S100-###-23
101 102 103 104 105 106
Max.Applicable
Motor Output(KW)
0.75 1.5 2.2 3.7 5.5 7.5
Max.Applicable
Motor Output(HP)
1 2 3 5 7.5 10
Rated Frequency(Hz) 0.1~400Hz
Rated Output
Current(A)
4.8 7.0 10 17 25 33
Rated Voltage 1.3 Phase
220VAC
±10%
3 Phase 220VAC±10%
Motor Current(A) 3.6 6.3 8.7 14 21 28
Motor Frequency(Hz) 60.00
Slipping Frequency(Hz) 3.00
Carrier Frequency(Hz) 1~15K
Cooling Method Forced Fan

380 Series:

Model Number
CY-S100-###-43
201 202 203 204 205 206
Max.Applicable
Motor Output(KW)
0.75 1.5 2.2 3.7 5.5 7.5
Max.Applicable
Motor Output(HP)
1 2 3 5 7.5 10
Rated Frequency(Hz) 0.1~400Hz
Rated Output
Current(A)
3 4.5 5.3 8 14 18
Rated Voltage 3 Phase 380VAC±10%
Motor Current(A) 2.1 3.6 5.0 7.8 12.2 16.2
Motor Frequency(Hz) 60.00
Slipping Frequency(Hz) 3.00
Carrier Frequency(Hz) 1~15K
Cooling Method Forced Fan

Applicable motor power Mounting Dimensions Enternal Dimensions Install Aperture(mm) Frame
Model A B H W D    
CY-S100-007-21A 76.8 131.6 140 85 115.3 4 A
Input & Output
Input Voltage Range 220V±15%
Input Frequency Range 47~63Hz
Output Voltage Range 0~rated input voltage
Output Frequency Range 0~400Hz
Protection Functions over voltage,over current,under voltage,overload,overload,overheating,electronic thermal,ground fault
I/O Features
Programmable Digital Input 4 input terminal
Programmable Analog Input AI2:0~10 or 0~20mA input
Programmable Open Collector Output 1 output terminal
Relay Output 1 output terminal
Analog Output 1 output terminal,whose output scope can be 0/4~20 mA
or 0~10 V, as chosen.
Main Control Function
Control Mode V/F control
Overload Capacity 60s with 150% of rated current, 10s with 180% of rated
current.
Carrier Frequency 0.5k~15.0kHz
Function Features
Frequency reference source keypad, analog input, multi-stage speed, simple PLC
Simple PLC, Multi-Steps Speed Control Function 8 stages speed can be set.
Traverse Control Function
None-Stop when instantaneous power off
QUICK/JOG Key User defined shortcut key can be realized
Automatic Voltage Regulation Function (AVR) Automatically keep the output voltage stable when input voltage fluctuating
Up to 25 fault protections Protect from over current, over voltage, under voltage,
over temperature, phase failure, over load etc.