Chang Yih inverter manufacturer

3 Phase 1HP~40HP

  • Current Vector Control Inverter 3 Phase 1HP~40HP
  • Current Vector Control Inverter 3 Phase 1HP~40HP
  • V/F & Sensorless Vector Control& Current
    Vector Control & Zero Servo
  • Support IPM& SPM motor
  • 200% torque performance at extreme low speed (0.5Hz), Overload 150% 60S
  • Support encoder feeback card
  • PID Feeback Control & Water Pump PID
  • Energy Saving & Automatic voltage regulation
  • Supports 2 independent induction motor control
  • Parameter sets output frequency 0.01-400Hz
  • Zero speed holding fun & Sleep/Revival Function
  • 6-set speed control & 15-set process control
  • Low noise, Carrier Frequency 1-15K
  • Product Description
  • Product Feature
  • Product Specification
Current Vector Control Inverter 3 Phase 1HP~40HP

230 Series:

Model Number
CY-S200- ### -23
100 101 103 104 105 106 107 108 109 110 111 112 113
Motor Output(KW) 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37
Motor Output(HP) 0.5 1 2 3 5 7.5 10 15 20 25 30 40 50
Rated Frequency(Hz) 0.01~400Hz
Rated Frequency(A) 3.1 4 7.1 10 17.5 22 32 45 62 71 86 120 140
Rated Voltage 3 Phase 220VAC±10%
Motor Current(A) 2.2 3.4 6.1 8.7 13.5 20.1 25.1 36.7 50.3 62.9 72.9 96.7 124
Motor Frequency(Hz) 60.00
Slipping Frequency(Hz) 3.00
Carrier Frequency(Hz) 1~15K
Cooling Method Forced Fan

440 Series:

Model Number
CY-S200- ### -43
200 201 202 203 204 206 207 208 209 210 211 212 213 214
Motor Output(KW) 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 37 45
Motor Output(HP) 0.5 1 2 3 5 7.5 10 15 20 25 30 40 50 60
Rated Frequency(Hz) 0.01~400Hz
Rated Frequency(A) 2 2.9 3.8 5.7 8.1 11 15.5 22.5 32 40 45 60 75 91
Rated Voltage 3 Phase 380/440VAC±10%
Motor Current(A) 0.9 1.6 2.8 4.1 6.8 9.9 12.7 18.9 24.7 31 37.6 48.1 64 75
Motor Frequency(Hz) 60.00
Slipping Frequency(Hz) 3.00
Carrier Frequency(Hz) 1~15K
Cooling Method Forced Fan

Current Vector Control Inverter 3 Phase 1HP~40HP
Current Vector Control Inverter 3 Phase 1HP~40HP
Current Vector Control Inverter 3 Phase 1HP~40HP
Current Vector Control Inverter 3 Phase 1HP~40HP

Applicable horsepower Model Mounting Dimensions External Dimensions Install Aperture(mm) Frame
    A B H W D    
220V 1HP
220V 2HP
220V 3HP
380V 1HP
380V 2HP
380V 3HP
CY-S200-101-23
CY-S200-103-23
CY-S200-104-23
CY-S200-201-43
CY-S200-202-43
CY-S200-203-43
106.6 175 185 118 154 4 B
220V 5HP
220V 7.5HP
220V 10HP
220V 15HP
380V 5HP
380V 7.5HP
380V 10HP
380V 15HP
CY-S200-105-23
CY-S200-106-23
CY-S200-107-23
CY-S200-108-23
CY-S200-204-43
CY-S200-206-43
CY-S200-207-43
CY-S200-208-43
148 235 247 160 175 5 C
220V 20HP
220V 25HP
220V 30HP
380V 20HP
380V 25HP
380V 30HP
380V 40HP
CY-S200-109-23
CY-S200-110-23
CY-S200-111-23
CY-S200-209-43
CY-S200-210-43
CY-S200-211-43
CY-S200-212-43
264 385 403.5 300 201.6 10 D
220V 40HP
220V 50HP
380V 50HP
380V 60HP
CY-S200-112-23
CY-S200-113-23
CY-S200-213-43
CY-S200-214-43
220 505 525 286 252 8 E
Control Characteristics Control Method SPWM Control (V/F, Sensorless Vector Control, V/F+PG, PMSV, PMSLV)
Torque Characteristics the auto-torque, auto-slip compensation; starting torquecan be 150% at 5.0Hz
Overload ability 150% of rated current for 1 minute
Accel/Decel Time 0.01 ~ 600seconds
V/F Curve Adjustable V/F Curve set up
stall Prevention 20 to 200%, Setting of Rated Current

 

Frequency Setting Keypad Setting by Keypad button (up/down)
External Signal Potentiometer-5KΩ/0.5W, 0 to +10VDC, 4 to 20mA, RS485 interface; Multi-Function Inputs 0 to 5 (7 steps, Jog, up/down)
Operation Setting Keypad Set by RUN, STOP
External Signal M0 to M5 can be combined to offer various modes of operation,RS-485 serial interface (MODBUS).
Multi-Function Input Signal Multi-step selection 1 to 7, Jog, accel/decel inhibit, first to forthaccel/decel switches, counter, PLC operation, external BaseBlock (NC, NO), UP/DOWN key settings, selections, driver reset
Multi-Function Output Indication Inverter operating, frequency reach, non-zero, base block, fault indication, local/remote indication, PLC operation indication, auxiliary motor output, overheat alarm, emergencystop
Analog Output Signal Analog frequency/current signal output
Operation Functions AVR, S-Curve, over-voltage, over-current stall prevention, faultrecords, adjustable carrier frequency, DC braking, momentary power loss restart, auto tuning, frequency limits, parameterLock/Reset, vector control,PID Control, counter, PLC, MODBUS communication, reverse inhibition, abnormal reset, abnormal restart, digital frequency output, sleep/revival function, frequency source selections
Protection Functions over voltage,over current, under voltage, overload, overheating, electronic thermal,ground fault
Cooling Method Forced Fan