Chang Yih inverter manufacturer

3 Phase 1HP~3HP 220V,380V

  • 3 phase vfd, 3 phase inverters
  • V/F& Sensorless Vector Control & Current Flux Control 
  • PID Feedback Control & Water Pump PID
  • Automatic torque boost & Slip compensation
  • Energy Saving & Automatic voltage regulation
  • Output Frequency 0.1~400Hz
  • Communication interface RS-485(Baud rate 38400 max.)
  • 8-set speed control & 7-set process control
  • Adjust S curve 、V/F curve & Simple vector control
  • Zero speed holding function & Sleep/Revival Function
  • Process follower 0-10VDC,4-20mA
  • Product Description
  • Product Feature
  • Product Specifications

230 Series:

Model Number
CY-S100-###-23
101 102 103 104 105 106
Max.Applicable
Motor Output(KW)
0.75 1.5 2.2 3.7 5.5 7.5
Max.Applicable
Motor Output(HP)
1 2 3 5 7.5 10
Rated Frequency(Hz) 0.1~400Hz
Rated Output
Current(A)
4.8 7.0 10 17 25 33
Rated Voltage 1.3 Phase
220VAC
±10%
3 Phase 220VAC±10%
Motor Current(A) 3.6 6.3 8.7 14 21 28
Motor Frequency(Hz) 60.00
Slipping Frequency(Hz) 3.00
Carrier Frequency(Hz) 1~15K
Cooling Method Forced Fan

380 Series:

Model Number
CY-S100-###-43
201 202 203 204 205 206
Max.Applicable
Motor Output(KW)
0.75 1.5 2.2 3.7 5.5 7.5
Max.Applicable
Motor Output(HP)
1 2 3 5 7.5 10
Rated Frequency(Hz) 0.1~400Hz
Rated Output
Current(A)
3 4.5 5.3 8 14 18
Rated Voltage 3 Phase 380VAC±10%
Motor Current(A) 2.1 3.6 5.0 7.8 12.2 16.2
Motor Frequency(Hz) 60.00
Slipping Frequency(Hz) 3.00
Carrier Frequency(Hz) 1~15K
Cooling Method Forced Fan
Applicable motor power Mounting Dimensions Enternal Dimensions Install Aperture(mm) Frame
Model A B H W D  
CY-S100-007-21A 76.8 131.6 140 85 115.3 4 A
CY-S100-101-23
CY-S100-102-23
CY-S100-103-23
CY-S100-201-43
CY-S100-202-43
CY-S100-203-43
103.6 175 185 118 154 4 B
CY-S100-104-23
CY-S100-105-23
CY-S100-106-23
CY-S100-204-43
CY-S100-205-43
CY-S100-206-43
148 235 247 160 175 5 C
Control
Characteristics
Control Method SPWM Control(V/F or Sensorless Vector Control)the auto-torque,auto-slip compensation;starting torque can be 150% at5.0Hz
Torque Characteristics the auto-torque,auto-slip compensation;starting torque can be 150% at 5.0Hz
Overload ability 150% of rated current for 1 minute
Accel/Decel Time 0.01~600 seconds
V/F Curve Adjustable V/F Curve set up
Stall Prevention 20 to 200%,Setting of Rated Current

 

Frequency Setting Keypad Setting by Keypad button(up/down)
External Signal Potentiometer-5KΩ/0.5W,0 to + 10VDC,4 to 20mA,RS485 interace;Multi-Funtion Inputs 0 to 5(7 steps,Jog,up/down)
Operation Setting Keypad Set by RUN,STOP
External Signal M0 to M5 can be combined to offer various modes of operation, RS-485 serial interface(MODBUS).
Mult-Function Input Signal Multi-step selection 1 to 7 ,Jog, accel/decel inhibit,first to forth accel/decel switches,counter,PLC operation,external Base Block(NC,NO),UP/DOWN key settings,selections,driver reset
Mult-Function Output Indication Inverter operating,frequency reach,non-zero,base block,fault indication,local/remote indication,PLC operation indication,auxiliary motor output,overheat alarm,emergency stop
Analog Output Signal Analog frequency/current signal output
Operation Functions AVR,S-Curve,over-voltage,over-current stall prevention,fault records,adjustable carrier frequency,DC braking,momentary power loss restart,auto tuning,frequency limits,parameter communication,reverse inhibition,abnormal reset, abnormal restart,digital frequency output,sleep/revival function,frequency source selections
Protection Functions over voltage,over current,under voltage,overload,overload,overheating,electronic thermal,ground fault
Cooling Method Forced Fan